一级黄色毛片免费观看_日韩精品在线免费观看_日韩一区欧美_操操操av_色婷婷综合久久_欧美a网站

Introduction

principle, structure

The vortex flowmeter is measured by the principle of Karman vortex street. A column is inserted vertically into the measuring tube. When the fluid passes through the column, under certain conditions, two columns of regular vortices will be alternately generated on both sides of the column, as follows As shown in the figure, these two rows of vortices are called "Kaman vortex streets". When d/D=0.281, the released vortices are the most stable. It can be simply expressed by the following formula:

F=St ×V/d

F: is the release frequency of the Karman vortex street

St: is the coefficient (called the Strohha number)

V: is the flow rate

d: column width

D: the inner diameter of the instrument

main feature

● Integrated liquid, gas or vapor mass flow meter

● Fully digital vortex street using DSP spectrum analysis technology and adaptive filtering technology

● Measurement vibration sensor independent of signal measurement sensor, excellent anti-vibration performance

● Excellent low flow rate performance; ultra-wide turndown ratio 17:1

● Probe design with built-in temperature

● Online replaceable testing pressure measurement design

● With 10-point nonlinear correction function

● Optional HART communication protocol or RS485 communication (MODBUS protocol)

● Modular circuit design and rich self-diagnosis function, easy maintenance

● Fast response speed, suitable for process control and automatic adjustment

● High temperature sensor can measure steam up to 400℃

● Electrical isolation between output and power supply, with excellent anti-interference ability

● The power supply has AC and DC, which is convenient for users to choose

application

fluid condition industry
gas                            Clean Metallurgy, papermaking, water treatment, chemical industry, light industry, textile, food and beverage, catering, agricultural irrigation, hydropower station, oil field, power and mining industries
dirty                                            
liquid Clean
Corrosive
dirty
steam Saturated Vapor
superheated steam

Performance overview

Flow meter, the base element is stainless steel or alloy. Applicable medium: liquid, gas, steam. The maximum working pressure is 40Mpa. The medium temperature is -50…360℃. Power supply: 12V~36VDC. Protection level IP68. Applicable pipe diameter 15-600mm. Unique DSP spectrum analysis technology.

technical parameter

size:Wafer type: DN15 to DN150
Flange type: DN15 to DN300
Insertion type: DN200 to DN2800
Fluid temperature:Conventional type: -30 to 280℃
High temperature type: -30 to 400℃
Sensor Material:Flange and housing:
Vortex Sounder:
Detector Material:
Connector material:
Temperature Sensor:PT100 is built in the detection probe, two-wire system
Pressure Sensor:Online repair and replacement available
Process connection:DIN PN10 to PN160
ANSI class 150、300、600、900、1500
HE 10k /HE 20K
Wafer
Pressure loss:Calculate the maximum pressure loss according to the formula on the right
Inlet pressure:When measuring liquid flow, the minimum requirement for the inlet pressure of the flowmeter is calculated according to the calculation formula
Reynolds number:10000<Re<700000
Ambient temperature range:-20 to 140O F (-29 to 60 ℃ )
shell material:Low copper die-cast aluminum Nema 4X, IEC60529 IP66 (standard), customizable stainless steel converter housing
Power supply:DC 16V to 36V, 1A fast blow fuse; AC 86V to 265V 50HZ/60HZ, 1A fast blow fuse
Current output:4 to 20 mA output, active output, isolated from the power supply, the relationship between the load resistance and the power supply refer to the relationship diagram below
Pulse output:0~5000HZ, active output, NPN mode, built-in pull-up resistor, duty cycle 50%
Switch output:High and low alarm, two sets of normally open contacts, driving capacity of 24VDC, 30mA, relays, alarm lights and valves with driving impedance greater than 800 ohms
show:LED liquid crystal, 4-line display, with backlight; the display digits of instantaneous flow and total volume are 9 digits
Instantaneous flow unit:m3/h、m3/m、m3/s、Gal、USAG/m、USAG/s、kg/h、kg/m、kg/s、t/h、t/m
Total unit:m3、Gal、L、kg、t
Temperature unit:°C
Pressure unit:Mpa
Density Units:kg/m3
Frequency unit:HZ
With 10-segment nonlinear processing function
Protocol:RS485 communication (modbus protocol)
Hart protocol optional
RS232 communication optional
Calibration function:4 to20mA calibration
temperature calibration
Pressure calibration
Protection class:IP65&IP68
Electrical interface:1/2NPT
power:max 3 watts

Selection table

FV10-Vortex flowmeter

installation type

Flange type (≤DN300 optional)

Flange type with temperature sensor

Flanged type with temperature and pressure sensor

Wafer type (≤DN150 optional)

Wafer type with temperature sensor

Wafer type with temperature and pressure sensor

Plug-in (≥DN200 optional)

structure type

Display unit integrated installation

Display unit split type installation

Applicable media

Measured fluid: liquid

Measured fluid: gas

Measured fluid: steam

Sensor temperature level

Conventional type (medium temperature≤280°C)

High temperature type (medium temperature≤400°C)

Pressure Level

EN 1092-1 (DIN) PN10
EN 1092-1 (DIN) PN16

EN 1092-1 (DIN) PN25
EN 1092-1 (DIN) PN40

EN 1092-1 (DIN) PN63
EN DN100 PN16 (Plug-in)

EN DN100 PN25 (Plug-in)
EN DN100 PN40 (Plug-in)

ASME B16.5(ANSI)CLASS150
ASME B16.5(ANSI)CLASS300

ASME B16.5(ANSI)CLASS600
ASME B16.5(ANSI)CLASS900

ASME 4inch CLASS150(Plug-in)
ASME 4inch CLASS300(Plug-in)

HE IS 10K
HE IS 20K

JIS 10K 4inch (plug-in)
JIS 20K 4inch (plug-in)

Product application specific standards


Power supply

DC: DC12V to 36V

output method

No output, on-site display purpose

4 ~ 20mA+ pulse signal

4~20mA+pulse signal+high and low flow alarm

Applicable pipe diameter

DN15,DN20,DN25,DN32,DN40,DN50,DN65,DN80,DN100,
DN125,DN150,DN200,DN250,DN300,DN350,DN400,
DN450,DN500,DN600,DN700,DN800,DN900,DN1000,
DN1200,DN1400,DN1600,DN1800,DN2000,DN2200,
DN2400,DN2600,DN2800

Body material

Stainless steel 1.4301(304)

Stainless steel 1.4435 (316L)

Detection element material

Stainless steel 1.4435 (316L)

Hastelloy
The complete data of this selection table, please contact the sales staff or email to sales@kewill-auto.cn for complete samples.
Prev :No
Next:No
主站蜘蛛池模板: 九九免费视频 | 四虎永久 | 电影一区二区在线观看 | 日韩成人一级片 | 国产天堂一区二区三区 | 成人情趣视频 | 91麻豆精品国产91久久久资源速度 | 国产精品欧美一区二区三区 | 国产综合亚洲精品一区二 | 亚洲午夜精品一区二区三区他趣 | 久久精品91 | 日韩精品免费 | 国产精品久久久久久久久免费丝袜 | 国产成人99久久亚洲综合精品 | 日本欧美在线观看 | 最新国产在线视频 | 亚洲精品动漫久久久久 | 亚洲国产精品一区二区第一页 | 玖玖玖视频 | 91av国产视频 | 久久精品中文 | 欧美综合一区二区 | 国产精品午夜电影 | 91精品国产综合久久久蜜臀粉嫩 | 午夜男人天堂 | av免费网站| 天天草影院 | 免费看91| 欧美精品在线观看 | 91成人在线 | 色视频久久| 免费黄色成人 | 国产色网 | 日韩精品在线一区 | 日韩精品观看 | 欧美视频一二三区 | 成人影| 成人免费视频视频在线观看 免费 | 久久久久久综合 | 欧美视频网站 | 久久久久久成人精品 |